Enjoy priority access to our reliable, experienced and highly skilled team of engineers throughout the year. Our service plan provides you with an annual boiler service and full central heating system inspections, starting at just £5.50 per month!
By taking out a service plan with Bishop Plumbing & Heating, you can enjoy 5% off all labour rates when booking in heating and plumbing services. That means lowering expenses with your boiler and heating systems start playing up.
Ready To Make Some Savings?
When the unexpected happens, and you’re left without a working boiler, it can be extremely expensive to repair. With our service plan, you can lower costs while accessing our experienced team in even the busiest times of the year, ensuring your boiler is well catered for, and your home kept warm.
Are You Ready To Design A Plan Catered To You & Your Budget?
Whether you are a domestic or commercial client, you can fully tailor your service plan to your needs. This allows you to ensure that your boiler is up and running throughout the year, with regular boiler checks, additional safety checks and exclusive discounts.
*Landlord Gas Safety Certificate is available on request at additional cost.
The service plan that you choose is completely up to you, your budget and your boiler and heating system. However, if you are unsure about which service plan is best for your home, then we recommend contacting our friendly team who can help you to understand more about the services provided in each plan and which is best suited to you.
Starting a service plan is easy. All you need to do is head over to our service plan page, choose the plan best suited to you, and click 'buy now'. If you have any questions about our service plan before purchasing, please feel free to contact the team!
Please download our PDF service plan document for further information and to find out more about arranging your contract. Feel free to contact the team with any queries you may have, and we look forward to helping you lower costs and protect your home against unexpected boiler breakdowns.
Our boiler broke down last year and cost so much to get fixed, it also happened just before Christmas, so we spent a few weeks in the freezing cold, which wasn’t pleasant! After having our boiler replaced with Bishop Plumbing, they told us about their service plan, and having had such a good experience with them we decided that it was the best way for us to save money. We have hardly had a problem with our boiler, but the team make sure that they check it all so that we don’t have an incident like before, and it’s nice to know that if anything did happen, we would be covered!
Marian Blake - 5th April 2020★★★★★
Piece Together Your Service Plan
Scroll Right
Landlord Safety Record
Landlord Safety Record Information
The landlords gas safety inspection will record each gas appliance and whether or not they are safe to use at the time of inspection. The full inspection will include the following:
Check the appliances for gas tightness
Check the standing and working pressure if test points are available
Check the burner pressure/gas rate against the manufacturer's data plate
Check for the satisfactory provision of all necessary ventilation
Test the flue flow to ensure removal of products of combustion
Check the satisfactory operation of safety devices
Check for physical stability, presence and effectiveness of brackets (where appropriate)
Investigate any evidence of unsafe operation and report to the landlord
Issue landlord gas safety record
Landlord Safety Record & Service
Boiler Service
Boiler Service Information
(For policies/plans that include a Boiler Service): The gas fired boiler at the property will be serviced to meet statutory requirements, manufacturer’s recommendations and relevant codes of practice. A full Boiler Service carried out will include the following:
A full inspection of the entire chimney structure inspection and, where necessary, cleaning of the burner, combustion chamber, any injectors and heat exchanger
Inspection of ignition devices i.e. pilot lights and/or spark and flame sensing electrodes
Checking the integrity of all seals and gaskets
Ensure that any condensate traps and drains are free from debris
Testing the appliance in accordance with manufacturer's instruction to ensure:
The heat input and/or operating pressure are correct
The effectiveness of the flue
That all ventilation requirements are to current standards
The correct operation of all safety devices and that the boiler is safe for continuous use
A final combustion analysis and measurement against tolerances set by the manufacturer's instructions
A test of any disturbed gas connections
Carry out functional testing of heating and hot water
A visual inspection of any other encountered gas appliances
Written notification of any gas safety defect which may affect the safe operation of your appliances
An assessment of your current heating controls and best practice advice regarding energy efficiency.
Unvented Cylinder Service
Boiler Service Plus Additional Appliances
Landlord Gas Safety Certificate CP12
Standing & working pressures
Standing & woring pressures Information
Check the standing and working pressure if test points are available
Burner Pressure
Burner Pressure Information
Check the burner pressure/gas rate against the manufacturer's data plate
Ventilation Checks
Ventilation Checks Information
Check for the satisfactory provision of all necessary ventilation
Flue Gas Analysis
Flue Gas Analysis Information
Test the flue flow to ensure removal of products of combustion
Inspect Safety Devices
Inspect Safety Devices Information
Check the satisfactory operation of safety devices
Flue & Chimney Inspection
Flue & Chimney Inspection Information
A full inspection of the entire chimney structure inspection and, where necessary, cleaning of the burner, combustion chamber, any injectors and heat exchanger
Inspect & Clean Ignition Devices
Inspect & Clean Ignition Devices Information
Inspection of ignition devices i.e. pilot lights and/or spark and flame sensing electrodes
Seals and Gaskets
Seals and Gaskets Information
Checking the integrity of all seals and gaskets. Note that if seals and gaskets are required this will be supplied at an additional cost
Inspect & Clean Condense Traps
Inspect & Clean Condense Traps Information
Ensure that any condensate traps and drains are free from debris
Operational Checks
Operational Checks Information
Testing the appliance in accordance with manufacturer's instruction to ensure:
The heat input and/or operating pressure are correct
The effectiveness of the flue
That all ventilation requirements are to current standards
The correct operation of all safety devices and that the boiler is safe for continuous use
Combustion Measurement & Analysis
Combustion Measurement & Analysis Information
A final combustion analysis and measurement against tolerances set by the manufacturer's instructions
Fill and Vent Heating System
Fill and Vent Heating System Information
Top up the system if required and check the operation of the filling loop, Check the filling loop for leaks and rectify where required. Vent system and bleed radiators
Heating & Hot Water Checks
Heating & Hot Water Checks Information
Carry out functional testing of heating and hot water
Service Record
Service Record Information
Written notification of any gas safety defect which may affect the safe operation of your appliances
Energy Efficiency Guidance
Energy Efficiency Guidance Information
An assessment of your current heating controls and best practice advice regarding energy efficiency.
Additional Appliances
Additional Appliances Information
landlord safety check includes Boiler and cooking appliance. If any other gas appliances are present then please select the landlord safety record & service
Spare Parts
Spare Parts Information
Please see our alternative services below if your appliance is faulty
Cylinder Service
Cylinder Service Information
Check the pressure on the heating system expansion vessel (1-1.5 Bar)
Test the operation of the pressure relief valve
Top up the system if required and check the operation of the filling loop
Check the filling loop for leaks and rectify where required
Check the electrics at the wiring centre
Check the manual bottle air eliminator and vent any excess air in the system
Check the operation of controller to ensure manual and automatic operation
Check operation of secondary return pump (where applicable)
Check the pressure in the expansion vessel (3 Bar)
Test the expansion relief & Temperature relief valves on the inlet control set for correct operation
Test the operation of the immersion heater and check the load
Test DWH 2 port valve for automatic and manual operation
Note: additional parts and labour may be charged extra. Before any annual service, we recommend you ask the engineer for their ID and qualifications, when they arrive.